* The AlphaCom XE software supports up to 500 RCO’s.
+
* The AlphaCom XE software supports up to 500 ''logical'' RCO’s.
* The RCO's are operated from the Event Handler.
+
* The logical RCO must be mapped to a '''Device''' or '''Station''', and to a '''Pin Number'''
* There are a number of commands available to operate RCO's, the most commonly used is the [[RCO - Set Remote Control Output|RCO command]]
+
* The logical RCO's are operated from the Event Handler.
 +
* There are several commands available to operate RCO's, the most commonly used is the [[RCO - Set Remote Control Output|RCO command]]
  
 
=== Mapping of RCO's ===
 
=== Mapping of RCO's ===

Revision as of 10:18, 27 May 2014

Examples of RCO usage

The Remote Control Output RCO’s are used to operate relays for control of external equipment.

Examples of usage:

  • Door opening
  • PA control
  • Call indication
  • Queue indication
  • Keying of mobile radio transmitter
  • CCTV interface


Devices supporting RCO’s

  • RCO outputs are available on a number of devices:
Device # of RCO's Comment Hardware required
AlphaCom XE26 138 6 RCO’s per ASLT card or ATLB-12 card MRBD relay board + PDB Power Distribution Board
AlphaCom XE20 102 6 RCO’s per ASLT card or ATLB-12 card MRBD relay board
AlphaCom XE7 12 Need ASLT in position 1 and/or 2 MRBD relay board
AlphaCom XE1 0 RCO's not available. Use IPARIO unit IPARIO unit
IPARIO unit (IP) 8 Remote outputs over IP network IPARIO unit
RIO unit (analog) 18 Remote outputs over RS232/485 MRBD relay board
IP Substation board (PCB 8022) 2 One relay on connector P3, pin 3/4 The second output is a logical signal. Transistor + relay required
IP Flush Master/IP OR station (PCB 8024) 2 One relay on connector P3, pin 3/4 The second output is a logical signal. Transistor + relay required
Turbine Compact/TKIS-2 kit 7 One relay included Use MRBD relay board if more than 1 relay is needed

Configuration

  • The AlphaCom XE software supports up to 500 logical RCO’s.
  • The logical RCO must be mapped to a Device or Station, and to a Pin Number
  • The logical RCO's are operated from the Event Handler.
  • There are several commands available to operate RCO's, the most commonly used is the RCO command

Mapping of RCO's

There are 500 logical RCOs. In AlphaPro there is a RCO mapping table where the logical RCO is assigned to a physical address. The physical address is given as device + pin-number or by station + pin number. The RCO command is used in the Event Handler to program the behavior of the RCO's defined in the RCO table.

The outputs can be used freely within the whole exchange, regardless of physical connections of the stations.

You can link an unlimited number of remote control outputs to one station. The outputs can be used simultaneously and programmed individually for any type of equipment using a closed or open contact for control. For example you can have a door station with remote control of the door lock combined with control of an external loudspeaker or a video camera.

The RCO set-up meets the following requirements:

  • Possibility to assign an unlimited number of remote control outputs (RCOs) per station.
  • A RCO can be switched ON by one event, and OFF by quite a different event at some later time.
  • A RCO can be configured to operate only when two specific stations are in conversation. This can be used, for example to control video cameras by relays. Another application is as access restriction, for example by allowing door opening only when certain stations are in conversation with a door.
  • It’s allowed to control one output by many events. The exchange always keeps track of the state of an output in case the device becomes faulty. When a faulty device becomes OK again, the exchange will restore the RCOs. The logical RCOs keeps track of the RCO’s state. Logical RCOs are assigned a physical device/pin number in a separate table that also will allow additional kinds of RCO hardware in the future.

Additional Information

  • For internal RCOs (ASLT/ATLB), the device address is 65, and the pin number is the same as the Physical number of stations, 1 - 552.
  • When the ATLB board is used in AlphaCom E7 only four RCO's are available
  • Mappings for the internal RCOs in the master are autoloaded. Mappings for RCOs in slave modules, RIO units and IP stations must be manually programmed.
  • In an AlphaNet installation you can control RCOs in a remote exchange.

Software

  • AMC 10.50 or later to control RCOs in slave modules. Earlier AMC versions support RCOs in master module only (pin 1 - 138).
  • AMC 10.04: Additional parameter to pulse the RCO ('RCO 12 ON 20' to generate a 2.0 sec pulse on RCO 12)
  • AMC 07.40 or later to control RCOs in an AlphaNet installation.