RCO - Remote Control Output
From Zenitel Wiki
The Remote Control Output RCO’s are used to operate relays for control of external equipment.
Relay outputs are typically used for:
- Door opening
- PA control
- Call indication
- Queue indication
- Keying of mobile radio transmitter
- CCTV interface
Contents
Devices supporting RCO’s
- RCO outputs are available on a number of devices:
Device | # of RCO's | Comment | Hardware required |
---|---|---|---|
AlphaCom XE26 | 138 | 6 RCO’s per ASLT card or ATLB-12 card | MRBD relay board + PDB Power Distribution Board |
AlphaCom XE20 | 102 | 6 RCO’s per ASLT card or ATLB-12 card | MRBD relay board |
AlphaCom XE7 | 12 | Need ASLT in position 1 and/or 2 | MRBD relay board |
AlphaCom XE1 | 0 | RCO's not available. Use IPARIO unit | IPARIO unit |
IPARIO unit (IP) | 8 | Remote outputs over IP network | IPARIO unit |
RIO unit (analog) | 18 | Remote outputs over RS232/485 | MRBD relay board |
IP Substation board (PCB 8022) | 2 | One relay on connector P3, pin 3/4 | The second output is a logical signal. Transistor + relay required |
IP Flush Master/IP OR station (PCB 8024) | 2 | One relay on connector P3, pin 3/4 | The second output is a logical signal. Transistor + relay required |
Turbine Compact/TKIS-2 kit | 7 | One relay included | Use MRBD relay board if more than 1 relay is needed |
Configuration
- The AlphaCom XE software supports up to 500 logical RCO’s.
- Each logical RCO must be mapped to a Device or Station, and to a Pin Number
- The logical RCO's are operated from the Event Handler.
- There are several commands available to operate RCO's, the most commonly used is the RCO command
Mapping of RCO's
There are 500 logical RCOs. In AlphaPro there is a RCO mapping table where the logical RCO is assigned to a physical address. The physical address is given as device + pin-number or by station + pin number. The RCO command is used in the Event Handler to program the behavior of the RCO's defined in the RCO table.
The outputs can be used freely within the whole exchange, regardless of physical connections of the stations.
Additional Information
- For internal RCOs (ASLT/ATLB), the device address is 65, and the pin number is the same as the Physical number of stations, 1 - 552.
- When the ATLB board is used in AlphaCom E7 only four RCO's are available
- Mappings for the internal RCOs in the master are autoloaded. Mappings for RCOs in slave modules, RIO units and IP stations must be manually programmed.
- In an AlphaNet installation you can control RCOs in a remote exchange.
Software
- AMC 10.50 or later to control RCOs in slave modules. Earlier AMC versions support RCOs in master module only (pin 1 - 138).
- AMC 10.04: Additional parameter to pulse the RCO ('RCO 12 ON 20' to generate a 2.0 sec pulse on RCO 12)
- AMC 07.40 or later to control RCOs in an AlphaNet installation.