Actions

Difference between revisions of "IP-ARIO"

From Zenitel Wiki

(Related Articles)
(Restore Factory Defaults and Software Upgrade)
 
(44 intermediate revisions by 3 users not shown)
Line 1: Line 1:
[[File:IP-ARIO.PNG|thumb|400px]]
+
{{Obsolete}}
 +
{{AI}}
 +
[[File:IP-ARIO.PNG|thumb|400px|IP-ARIO, Item Number: 1008095100]]
 +
 
 +
This product is discontinued.
 +
Replacement depends on type of use (see [[Kits - Comparison chart]]):
 +
* For PA integration, use [[TKIS-2]]
 +
* For Mobile Radio Integration  use [[TKIE-2]]
 +
* For I/O, use [[IP-LCM]]
 +
 
 
The IP Audio Remote I/O ('''IP-ARIO''') unit has a wide set of hardware functions. It can be used as:
 
The IP Audio Remote I/O ('''IP-ARIO''') unit has a wide set of hardware functions. It can be used as:
 +
*PA Interface over IP
 +
*Radio Interface over IP
 +
*Remote I/O unit over IP
 +
*Remote AlphaCom RS232 port over IP
  
===<u>Highlights</u>===
+
== Requirements ==
* PA Interface over IP
+
'''Software:'''
* [[Mobile_radio_interface_(IPARIO)|Mobile Radio Interface]] over IP
 
* Remote I/O Unit over IP
 
* Remote AlphaCom RS232 port over IP
 
* Integrated 2-port Ethernet switch
 
* PoE and/or 24VDC powered
 
 
 
===<u>Software Requirements</u>===
 
 
* AMC-IP version 11.2.3.1 or newer
 
* AMC-IP version 11.2.3.1 or newer
 
* AlphaPro Version 11.2.3.0 or newer
 
* AlphaPro Version 11.2.3.0 or newer
  
===<u>License Requirements</u>===
+
'''Server:'''
An [[Licenses#IP-ARIO_Audio_License|IP-ARIO Audio License]] is required in the AlphaCom when the audio part of IP-ARIO is used, i.e. when the IP-ARIO is used as PA interface or as a Mobile Radio interface. To install the license, log on to [[AlphaWeb]]:
+
* AlphaCom server is required
* Select '''System Configuration > Licensing'''
+
* The IP-ARIO is not supported in Pulse or SIP mode.
* Click '''Insert new License Key'''
 
[[File:IP-ARIOConfig11.PNG|tumb|left|500px]]
 
<br style="clear:both;" />
 
 
 
* Enter the key string in the '''Input License Key''' field
 
* Click '''Insert Key''' to install the license.
 
  
'''Note:''' If only the I/O part of the IP-ARIO is used, no license is required. The AlphaCom will automatically recognize the unit as an IP-ARIO and allow it to register without a license.
+
== License Requirements ==
 +
* An [[Licenses#IP-ARIO_Audio_License|IP-ARIO Audio License]] is required in the AlphaCom when the audio part of IP-ARIO is used, i.e. when the IP-ARIO is used as PA interface or as a Mobile Radio interface.
 +
* If only the I/O part of the IP-ARIO is used, no license is required. The AlphaCom will automatically recognize the unit as an IP-ARIO and allow it to register without a license.
  
===<u>[[IP-ARIO Connections|InterCom connections]]</u>===
+
== Connections ==
 +
* [[IP-ARIO Connections|IP-ARIO connections]]
  
===<u>Configuration</u>===
+
==Configuration==  
 
* [[IP-ARIO Configuration]]
 
* [[IP-ARIO Configuration]]
* [[IP-ARIO AlphaPro Configuration|AlphaPro Configuration]]
 
  
===<u>[[INCA Station Software upgrade|Software Upgrade]]</u>===
+
== Advanced Network Settings ==
 +
* [[VLAN Tagging (IEEE 802.1Q)]]
 +
* [[IEEE 802.1X|Network Access Control (802.1X)]]
  
===<u>[[IP-ARIO LED Indicators|LED Indications]]</u>===
+
== Restore Factory Defaults and Software Upgrade ==
 +
* [[IP-ARIO Restore Factory Defaults|Reset to factory settings]]
 +
* [[INCA Station Software upgrade|Upgrade via the station web interface]]
 +
* [[IMT - Discover & Upgrade|Upgrade using the IMT tool]]
 +
* [[:Category:INCA Release notes|Software Release Notes]]
  
===<u>[[IP_ARIO Dimensions & Mounting Instructions|Dimensions]]</u>===
+
== Dimensions ==
 +
*[[IP_ARIO Dimensions & Mounting Instructions|Dimensions]]
  
===<u>[[IP-ARIO Restore Factory Defaults|Reset to factory settings]]</u>===
+
== Accessories ==
 +
* [[IP ARIO Dimensions & Mounting Instructions|Mounting brackets]]
  
===<u>[http://www.zenitel.com/product/ip-ario Additional Documentation on Zenitel.com]</u>===
+
== Software Requirements ==
 
+
This station is fully supported as form AlphaCom version 11.2.3.1
[[Category: INCA Stations]]
 
  
 +
== Related information ==
 +
* [http://www.zenitel.com/product/ip-ario Additional Documentation on Zenitel.com]
  
  
 
[[Category: INCA Stations]]
 
[[Category: INCA Stations]]
 
==Mandatory Configuration==
 
 
==Configuring PA interface==
 
In AlphaPro, '''Users & Stations''', select the IP-ARIO from the list box, and click the '''Station Type''' tab.
 
Under '''IP-ARIO''', set the following flags:
 
* Check the '''XLR PA Monitoring''' box
 
* Check the '''2 Amplifiers''' box
 
* Check the '''Request Audio License''' box
 
 
[[File:IP-ARIOConfig2.PNG|thumb|left|500px]]
 
<br style="clear:both;" />
 
 
==Configuring Mobile Radio Interface==
 
The IP-ARIO unit should be defined as Default Speaker in the Simplex Conference used for radio listening.
 
* In AlphaPro, click the '''Simplex Conferences''' icon.
 
[[File:AlphaPro SX conference icon.jpg]]
 
* Select a Conference and click '''Change'''
 
* Select the IP-ARIO as the '''Default Member'''
 
* Enable '''Default Member is Default Speaker'''
 
[[File:IP-ARIOConfig3.PNG|thumb|left|500px|Define IPARIO as Default Speaker in the conference]]
 
<br style="clear:both;" />
 
 
In the '''Users & Stations''' window, click the '''Station Type''' tab.
 
Under '''IP-ARIO''', set the following flag:
 
* Check the '''Request Audio License''' box
 
 
 
See [[Mobile radio interface (IPARIO)]] for further details.
 
 
==Configuring Inputs & Outputs==
 
Remote Control Inputs & Outputs are configured under the Exchange & System menu. <br/>
 
[[File:Exchange icon.jpg]] <br/>
 
For Remote Control Inputs:
 
* Click '''RCI'''
 
* Click '''Change''' to set '''RCI Type''' to '''Station'''
 
* Enter the IP-ARIO Directory number in the '''Station Number''' field
 
* Enter a '''Pin Number''' 1 to 8. Pin 1 is input 1, pin 2 is input 2 etc.
 
[[File:IP-ARIOConfig4.PNG|thumb|left|500px]]
 
<br style="clear:both;" />
 
 
For Remote Control Outputs:
 
* Click '''RCO'''
 
* Click '''Change''' to set '''RCO Type''' to '''Station'''
 
* Enter the IP-ARIO Directory number in the '''Station Number''' field
 
* Enter a Pin Number 1 to 8. Pin number 1 is output 1, pin number 2 is output 2 etc.
 
[[File:IP-ARIOConfig5.PNG|thumb|left|500px]]
 
<br style="clear:both;" />
 
 
==Configuring Remote Serial Port==
 
Click the '''Exchange & System''' icon and click '''Serial Ports'''. <br/>
 
[[File:Exchange icon.jpg]] <br/>
 
* Select one of the '''EDIO''' drivers and click '''Change'''
 
[[File:IP-ARIOConfig6.PNG|thumb|left|500px]]
 
<br style="clear:both;" />
 
 
* Check the '''Enabled''' box
 
* Set '''Port Type''' to '''IP-PARIO'''
 
* Enter the '''physical number''' of the unit in the '''Station''' field
 
* Enter the '''port number''' in the '''Port''' field
 
** The port number (e.g. 4000) must be defined and opened under '''Filters''' in AlphaWeb
 
* Click '''OK'''
 
[[File:IP-ARIOConfig7.PNG|thumb|left|500px]]
 
<br style="clear:both;" />
 
 
==Local Status Monitoring==
 
The Local Status Monitoring (LSM) feature can be started anytime after booting up the IP-ARIO unit. LSM will show the status on the following monitored items:
 
* PA 1 and PA 2 for 20 kHz speaker monitoring
 
* XLR 1 and XLR 2 for XLR connectors connection status
 
* RCI 1 to RCI 8 showing active or non-active RCI inputs
 
* RCO 1 to RCO 8 showing active or non-active RCO outputs
 
<br/>
 
LSM is started by using a pin to press the pinhole Reset button located on the front-right of the unit. All LEDs at the front of the unit will be lit as long as the Reset button is pressed (as visual verification of the LED status). When the Reset button is released, LSM continues and the LEDs will show the following:
 
* '''CALL''' LED fast flashing to indicate that the LSM feature is active.
 
* '''STATUS''' LED indicates monitored group (3 groups)
 
** PA/XLR (green off, red off)
 
** RCI (green on, red off)
 
** RCO (green off, red on)
 
* '''RADIO''' LED indicates monitored item within group, mix of LEDs on, off, slow and fast flashing.
 
* '''ERROR''' LED indicates status of monitored item, on if fail or active, off if OK or non-active.
 
<br/>
 
PA/XLR needs approximately 10 seconds to be updated if the status changes, i.e. if the XLR connector is disconnected and then reconnected. <br/>
 
RCI and RCO will show instant updating if the status changes, i.e. if RCI 1 changes status, this will be immediately indicated on the '''ERROR''' LED if RCI 1 is monitored. <br/>
 
Each time the Reset button is toggled, the status of the next LSM item is indicated on the '''ERROR LED'''. <br/>
 
The LSM can be terminated at any time by pressing and holding the Reset button for at least 2 seconds. LSM will auto-terminate 2 minutes after the last Reset button
 
activity. <br/>
 
The table below shows the relation between the current status of the monitored item and the different LED indicators.
 
<br/>
 
<br/>
 
 
{| border="1"
 
|-
 
!colspan="9" align="center" style="background:#ffcb00;"|Local Status Monitoring
 
|-
 
!colspan="2" style="background:#ffcb00;"| ||colspan="7" align="center" style="background:#ffcb00;"|Front LEDs
 
|-
 
!colspan="2" style="background:#ffcb00;"| ||align="center" style="background:#ffcb00;"|CALL||colspan="2" align="center" style="background:#ffcb00;"|STATUS||colspan="2" align="center" style="background:#ffcb00;"|RADIO||colspan="2" align="center" style="background:#ffcb00;"|ERROR
 
|-
 
!style="background:#ffcb00;" width="120pt"|Toggle #
 
!style="background:#ffcb00;" width="120pt"|Monitored Item
 
!style="background:#ffcb00;" width="120pt"|Green
 
!style="background:#ffcb00;" width="120pt"|Color
 
!style="background:#ffcb00;" width="120pt"|Indication
 
!style="background:#ffcb00;" width="120pt"|Color
 
!style="background:#ffcb00;" width="120pt"|Indication
 
!style="background:#ffcb00;" width="120pt"|Red:ON
 
!style="background:#ffcb00;" width="120pt"|Red:OFF
 
|-
 
!| 0
 
!| PA 1
 
!| FAST
 
!| NONE
 
!| OFF
 
!| GREEN
 
!| ON
 
!| Fail
 
!| OK
 
|-
 
!| 1
 
!| PA 2
 
!| FAST
 
!| NONE
 
!| OFF
 
!| GREEN
 
!| SLOW
 
!| Fail
 
!| OK
 
|-
 
!| 2
 
!| XLR 1
 
!| FAST
 
!| NONE
 
!| OFF
 
!| RED
 
!| ON
 
!| Fail
 
!| OK
 
|-
 
!| 3
 
!| XLR 2
 
!| FAST
 
!| NONE
 
!| OFF
 
!| RED
 
!| SLOW
 
!| Fail
 
!| OK
 
|-
 
!| 4
 
!| RCI 1
 
!| FAST
 
!| GREEN
 
!| ON
 
!| GREEN
 
!| ON
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 5
 
!| RCI 2
 
!| FAST
 
!| GREEN
 
!| ON
 
!| GREEN
 
!| SLOW
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 6
 
!| RCI 3
 
!| FAST
 
!| GREEN
 
!| ON
 
!| GREEN
 
!| FAST
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 7
 
!| RCI 4
 
!| FAST
 
!| GREEN
 
!| ON
 
!| RED
 
!| ON
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 8
 
!| RCI 5
 
!| FAST
 
!| GREEN
 
!| ON
 
!| RED
 
!| SLOW
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 9
 
!| RCI 6
 
!| FAST
 
!| GREEN
 
!| ON
 
!| RED
 
!| FAST
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 10
 
!| RCI 7
 
!| FAST
 
!| GREEN
 
!| ON
 
!| YELLOW
 
!| ON
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 11
 
!| RCI 8
 
!| FAST
 
!| GREEN
 
!| ON
 
!| YELLOW
 
!| SLOW
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 12
 
!| RCO 1
 
!| FAST
 
!| RED
 
!| ON
 
!| GREEN
 
!| ON
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 13
 
!| RCO 2
 
!| FAST
 
!| RED
 
!| ON
 
!| GREEN
 
!| SLOW
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 14
 
!| RCO 3
 
!| FAST
 
!| RED
 
!| ON
 
!| GREEN
 
!| FAST
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 15
 
!| RCO 4
 
!| FAST
 
!| RED
 
!| ON
 
!| RED
 
!| ON
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 16
 
!| RCO 5
 
!| FAST
 
!| RED
 
!| ON
 
!| RED
 
!| SLOW
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 17
 
!| RCO 6
 
!| FAST
 
!| RED
 
!| ON
 
!| RED
 
!| FAST
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 18
 
!| RCO 7
 
!| FAST
 
!| RED
 
!| ON
 
!| YELLOW
 
!| ON
 
!| Active
 
!| Non-ACTIVE
 
|-
 
!| 19
 
!| RCO 8
 
!| FAST
 
!| RED
 
!| ON
 
!| YELLOW
 
!| SLOW
 
!| Active
 
!| Non-ACTIVE
 
|-
 
|}
 
 
'''SLOW''' means slow flashing at 500 ms on and 500 ms off. <br/>
 
'''FAST''' means fast flashing at 250 ms on and 250 ms off. <br/>
 
  
 
=Related Articles=
 
=Related Articles=
* [[PA Failure State System]] <br/>
+
* [[PA Failure State System]]
 +
* [[Mototrbo and AlphaCom interfacing]]
 +
* [[IP station as program]]
  
[[Category: INCA Stations]]
+
[[Category: Discontinued Stations]]
 
[[Category: IP-ARIO]]
 
[[Category: IP-ARIO]]
[[Category: Public Address]]
+
[[Category: Public Address - Interfaces]]
 +
[[Category: Additional equipment]]

Latest revision as of 09:18, 16 August 2022

Obsolete icon This product is discontinued!


AI.png
IP-ARIO, Item Number: 1008095100

This product is discontinued. Replacement depends on type of use (see Kits - Comparison chart):

  • For PA integration, use TKIS-2
  • For Mobile Radio Integration use TKIE-2
  • For I/O, use IP-LCM

The IP Audio Remote I/O (IP-ARIO) unit has a wide set of hardware functions. It can be used as:

  • PA Interface over IP
  • Radio Interface over IP
  • Remote I/O unit over IP
  • Remote AlphaCom RS232 port over IP

Requirements

Software:

  • AMC-IP version 11.2.3.1 or newer
  • AlphaPro Version 11.2.3.0 or newer

Server:

  • AlphaCom server is required
  • The IP-ARIO is not supported in Pulse or SIP mode.

License Requirements

  • An IP-ARIO Audio License is required in the AlphaCom when the audio part of IP-ARIO is used, i.e. when the IP-ARIO is used as PA interface or as a Mobile Radio interface.
  • If only the I/O part of the IP-ARIO is used, no license is required. The AlphaCom will automatically recognize the unit as an IP-ARIO and allow it to register without a license.

Connections

Configuration

Advanced Network Settings

Restore Factory Defaults and Software Upgrade

Dimensions

Accessories

Software Requirements

This station is fully supported as form AlphaCom version 11.2.3.1

Related information

Related Articles