Actions

Difference between revisions of "SIP phone as station"

From Zenitel Wiki

(Feature list)
(Feature list)
Line 114: Line 114:
 
|}
 
|}
  
*(1) The SIP phone need to register with a second account (requiring a second SIP phone license). The second account must have AutoAnswer enabled, and be included in the group call. The flag "Allow SIP Stations in Group Calls and as default speaker in SX Conference" must be enabled in [[Exchange_%26_System_(AlphaPro)#VoIP|AlphaPro - Exchange & System > System > VoIP]]
+
*(1) The SIP phone needs to register with a second account (requiring a second SIP phone license). The second account must have AutoAnswer enabled, and be included in the group call. The flag "Allow SIP Stations in Group Calls and as default speaker in SX Conference" must be enabled in [[Exchange_%26_System_(AlphaPro)#VoIP|AlphaPro - Exchange & System > System > VoIP]]
 
*(2) Volume is set locally from the phone. Volume cannot be controlled from the ICX-AlphaCom server. [[Volume and handset override|Volume Override]] is not supported.
 
*(2) Volume is set locally from the phone. Volume cannot be controlled from the ICX-AlphaCom server. [[Volume and handset override|Volume Override]] is not supported.
 
*(3) xxx
 
*(3) xxx

Revision as of 09:22, 15 October 2020

AlphaCom icon 300px.png
AlphaCom XE as SIP Server

This article describes how to configure SIP users in the AlphaCom XE server, and shows a feature comparison between SIP users and STENTOFON intercom stations.

Examples of SIP users are:

  • VoIP telephones
  • PC clients (Softphones)
  • WiFi phones
  • IP Dect systems
  • Analog Telephone Adapter (ATA)

The AlphaCom XE supports up to 500 SIP users.

A "SIP station" license is required for each SIP phone. The license is available in stages of 1, 6, 12 and 36 SIP users.



Software requirements

  • AMC 10.56 or higher
  • AlphaPro 10.56 or higher

In AMC software prior to 10.56, SIP users had to register via a virtual SIP Registrar node. This was a more complicated solution, with less functionality.

AlphaCom Configuration

AlphaWeb Configuration

  • Licenses: Each SIP user requires a "SIP station" license. In AlphaWeb, go to System Configuration -> Licensing, and Insert the license key containing the SIP Station license.
  • Filter settings: The ports used for SIP protocol (5060) and the VoIP Audio must be enabled for the ethernet port used by the SIP users. In AlphaWeb, go to System Configuration -> Filters, and enable the UDP ports for SIP (5060) and for VoIP Audio (61000:61150). By default these ports are enabled on ethernet port 1.

AlphaPro Configuration

SIP users are related to "physical" numbers in the same manner as STENTOFON IP stations.

  • From the Users & Stations window in AlphaPro, select a free user from the listbox, and enable the SIP station flag
  • Configure Directory Number and Display Text
  • Select a supported Codec for the SIP station to use
SIP phones are configured in the Users & Stations window in AlphaPro


SIP phone Configuration

General

When starting to dial a number on a SIP phone, the digits are collected in the phone before the complete number is sent to the AlphaCom for interpretation. This will not give any feedback to the user before the collected digits are sent to the AlphaCom. The number is usually sent by pressing the handset button, a dedicated “send” key or after timeout. Event Handler events are not activated before the SIP phone has sent the number. (E.g. the Station in Use event will not be triggered when the user starts to dial locally).

SIP phones have various local set-up and configuration options. The level of integration will depend on the configuration available on the current phone model.

Basic Integration Level

SIP phones without SIP INFO signaling will give basic integration level. These phones will not be able to do any feature activation during conversation or use features requiring extra parameters. Features during conversation, such as Inquiry and transfer will not work. Features requiring extra parameters like WakeUp call and Follow Me will also not work.

Minimum configuration of the SIP phone:

  • The IP address of AlphaCom (Typically referred to as SIP Server, Registration Server, Domain, Proxy Domain, User Domain)
  • Directory number matching the directory number configured in AlphaPro
  • Codec matching the codec configured in AlphaPro

Medium Integration Level

SIP phones supporting SIP INFO digit signaling will give medium integration level. With these phones further dialing after activation of a feature like Inquiry or WakeUp Call will be supported by SIP INFO signaling.

Additional configuration of the SIP phone:

  • Enable digit signalling with SIP INFO signalling.

Note that DTMF signalling in Audio band must be turned off if SIP trunks are to be used.

Best Integration Level

SIP phones supporting SIP INFO digit signaling, "Automatic dialing when Off-Hook" and "Auto-Answer".

These phones give these additional features:

  • Automatic dialing when Off-Hook: Hotline Call. When lifting handset the SIP phone will do an automatic setup of a call.
  • Auto-answer: Option to automatically connect an incoming call, without the need of lifting the handset.


Feature support

In principle SIP users have the same features and settings available as Stentofon stations. However, because of the limitations of the SIP phones and protocol, some features are not supported.

Feature list

Feature SIP Phones (incl ITSV) Zenitel IP Stations
Point to point calls V V
Caller ID V V
Duplex Conference V V
Door opening (6) V V
Send Call Request V V
Member of Ringing Group V V
Line Down reporting V V
Receive Call Request (Call Queuing) X V
Simplex Conference X V
Audio Program X V
Receive Group Calls V (1) V
Receive Voice Alarm Messages V (1) V
Receive Mail Messages (Station errors etc.) X V
Status info in display (Call Forwarding, Absence status etc.) X V
Volume setting V (2) V
Hotline call V (3) V
Group Hunt member X V
Line Monitoring via Tone test X V
  • (1) The SIP phone needs to register with a second account (requiring a second SIP phone license). The second account must have AutoAnswer enabled, and be included in the group call. The flag "Allow SIP Stations in Group Calls and as default speaker in SX Conference" must be enabled in AlphaPro - Exchange & System > System > VoIP
  • (2) Volume is set locally from the phone. Volume cannot be controlled from the ICX-AlphaCom server. Volume Override is not supported.
  • (3) xxx

About Line Down reporting

Line down reporting on SIP phones is based on the "Registration expire" time out. This timeout is default several hours on most SIP phones. If faster fault reporting is needed the timeout must be adjusted.

The timeout can also be adjusted as a general parameter in AlphaCom NVRAM:

ex_profile.timeouts.sip_max_expire

0 = Use time out as defined in the SIP phones
0< = Time out in seconds

About Hotline Call

Hotline call is only available from SIP stations with best level of integration with option for "off hook auto dialling".
When this is configured the SIP phone will get the AlphaCom dial tone when lifting the handset and the hotline timer is started.