Search results
Create the page "Event Handler applications" on this wiki! See also the search results found.
- ==Event Handler== This is done using the [[Event Handler]]. Select '''Exchange & System''' from the top menu in [[AlphaPro]]:1 KB (166 words) - 11:12, 8 July 2022
- ==Event Handler== This is done using the [[Event Handler]]. Go to Exchange & System from the top menu in [[AlphaPro]]:982 bytes (148 words) - 13:48, 31 May 2022
- The stations dial an Event Trigger number ([[Event Trigger with cancel tone feature|feature 85]]), say number 9533, to pulse t ...nts|Exchange and System -> Events]], press Insert and create the following event:775 bytes (106 words) - 11:34, 8 July 2022
- ==Event Handler== Use the event handler (Exhcange&System->Events) to create this event:1 KB (240 words) - 16:20, 31 May 2022
- This event will set the whole exchange in simplex (Press To Talk) mode. Simplex mode w ...nts|Exchange and System -> Events]], press Insert and create the following event:1 KB (175 words) - 11:37, 8 July 2022
- ...the "Event Owner" or the "Related To" parameter. It can be useful in some applications, especially in [[RCI]] strings were there by default is no parameters. The OWN 101 – sets the event owner to dir.no. 101761 bytes (117 words) - 16:16, 4 October 2019
- Here dialing the event trigger 9534 will remove all members of group 48. ...nts|Exchange and System -> Events]], press Insert and create the following event:873 bytes (122 words) - 11:35, 8 July 2022
- The Delayed Call functionality is controlled by the [[Event Handler]], which is configured from [[AlphaPro]]. '''Event 1''' - When the call button (Subevent = 1) is pressed (=ON), start a 3 seco1 KB (218 words) - 11:21, 8 July 2022
- Use the two-step event trigger, [[Event trigg on dialing digits|feature 105]]. ...nts|Exchange and System -> Events]], press Insert and create the following event:1 KB (194 words) - 11:14, 8 July 2022
- '''Event 1''' '''Event 2'''1 KB (188 words) - 11:32, 8 July 2022
- Use the event type “[[Call Requester Mode (Event Type)|Call Requester Mode]]” on the cell stations to set/reset call forwa ...:''' Set transfer to 'dummy' number 345 when not in [[Call Requester Mode (Event Type)|Call Requester Mode]].2 KB (225 words) - 11:36, 8 July 2022
- ...rivate Ringing mode (Event Type)|9 - Private Ringing mode]] in the [[Event Handler]], one can change the volume during the ringing, and set it to a normal lev ...nts|Exchange and System -> Events]], press Insert and create the following event:2 KB (320 words) - 11:22, 8 July 2022
- The '''%udd''' macro is used in the [[Event Handler]] to read the value of an [[UDD]] (User Defined Data variable). [[Event_Han ...turns the content of UDD variable in indexed by the physical number of the event 'Owner'''1 KB (192 words) - 09:50, 4 October 2019
- ...ation. 9535 must be defined as [[Event Trigger with parameter (Event Type)|Event Trigger with parameter]], feature 95. '''Event 1''' - When a station is called, store the directory number of the calling2 KB (250 words) - 13:48, 14 December 2023
- ...ult reporting, and how to use customized error reporting using the [[Event Handler]] instead. == Configure Station Error reporting in Event Handler ==3 KB (412 words) - 14:02, 31 May 2022
- == DAK event == In the [[Event Handler]], the event 30 (Station Input or Station DAK key) is triggered when a DAK Key is presse1 KB (197 words) - 14:24, 31 May 2022
- The event type 25 is triggered by a so-called "two-step" event trigger. There are two different types, one which waits for a complete dire * [[Event Trigger w/User Parameter|Feature 95]] (Default 9535): Dial 9535 + dir no4 KB (589 words) - 10:28, 30 March 2023
- ==Event description== |width="200pt"|'''Event Owner''':2 KB (251 words) - 10:48, 9 February 2023
- Door opening of Ring Master stations from AlphaCom is configured by using [[Event During Connection]] and DP message [[DTMF_CONN]] [[Event During Connection]] configured as directory number "6" (Door opening)1 KB (167 words) - 10:47, 1 June 2022
- ...andard feature for displaying '''Missed calls''', but by using the [[Event Handler]], one can create such function. ...phaPro, select '''Exchange & System''' > '''Events''', and '''Insert''' an event with the following properties:1 KB (160 words) - 14:30, 31 May 2022
- ...s reporting conference membership. The event type [[Conversation Outgoing (Event Type)|08 - Conversation Outgoing]] is triggered when a station is talking i ...Room Station is located. This event report message will in turn trigger an event in the node with the Control Room Station, which is used to control the LED3 KB (422 words) - 11:30, 8 July 2022
- The Event Type [[Private Ringing Outgoing(Event Type)|33 - Private Ringing Outgoing]] can be used to forward unattended SIP '''Note''' - The event type 33 require AMC 10.30 or later.2 KB (278 words) - 12:21, 24 February 2023
- [[Category:AlphaCom Applications]] [[Category:ICX-AlphaCom Applications]]1 KB (189 words) - 11:32, 8 July 2022
- ...nts|Exchange and System -> Events]], press Insert and create the following event: ...d ringing signal should be played in the loudspeaker of the initiator this event must be used:2 KB (290 words) - 10:54, 5 May 2023
- ...station will be moved to a COS were all features are disabled, except the event trigger feature itself. * In AlphaPro - Directory & Features, '''Insert''' a new event trigger directory number with feature number 85, e.g. 9200.2 KB (336 words) - 08:04, 1 June 2022
- The '''WUDD''' command is used in the [[Event Handler]] to write a value to [[UDD]] (User Defined Data variable). The value is ch From AMC 11.02 alphanumeric storing from event handler is possible (not via $WUDD). Alphanumeric storing is cleared after reset.2 KB (282 words) - 16:19, 4 October 2019
- ...editor in the [[TST console]] or the [[SNV|$SNV command]] from the [[Event Handler]]. ====Using the Event Handler ====2 KB (352 words) - 16:09, 20 July 2022
- * This event is CPU extensive. Maximum members in a group using this feature '''should n When stations outside UDP group 2 dial group call 86 this event will not be triggered, and the volume will not be altered.2 KB (315 words) - 15:22, 11 August 2022
- ...ty. An '''UDP group''' is a group of stations that are used by the [[Event Handler]] to construct rules that applies to a group of stations. There are 8 UDP g An Event Handler rule can refer to an UDP group in the condition part. Both the "owner" and3 KB (453 words) - 13:45, 11 May 2022
- ...station. This is the '''Group Configuration''' button. Directory number [[Event Trigger w/User Parameter|9535]] is included in a default database. ===Event Handler configuration===4 KB (649 words) - 11:13, 8 July 2022
- [[File:PCStream2.png|thumb|left|700px|Event Handler]] [[Category:AlphaCom Applications]]1 KB (166 words) - 14:07, 16 February 2024
- ...n Input or Station DAK key (Event Type)|Station Input or Station DAK key]] event programmed to check a UDD before sending a [[mail]] to the Staff stations. ==Event Handler programming==5 KB (815 words) - 14:02, 16 November 2023
- ...Step Event Trigger w/User Parameter]], 9535 (feature 95/0). The programmed event reads the dialed directory number and commands the substation to enter a co ==Event Handler programming==4 KB (551 words) - 10:33, 8 June 2023
- ...+ Substation is dialed, an [[Event_Trigger_with_parameter_%28Event_Type%29|event type 25]] is triggered and the action string [[SET_STATION_COS|$SSC L%2.dir When the timer expires it will trigger [[Event_Timeout_%28Event_Type%29|event type 21]], and the command [[SET_STATION_COS|$SSC L%1.dir U1]] will move th3 KB (541 words) - 09:52, 8 July 2022
- The [[Event Handler]] is used to control the [[RCO]]'s which operate the relays. In the example '''Event 1''' - When a conversation is made from the master station to the substatio4 KB (600 words) - 11:12, 8 July 2022
- ===Create Event Trigger Number=== The number dialled by the user will actually be an Event Trigger. This must be added in the AlphaCom directory table as ''feature''4 KB (678 words) - 12:05, 24 February 2023
- ==Event Handler programming== '''Event 1''' - CALL event5 KB (836 words) - 15:18, 6 January 2023
- ...ink Layer|simple link layer]], but only for single-exchange (not AlphaNet) applications. ...it’s possible to send additional data strings from the AlphaCom’s [[Event Handler]] on this port also.993 bytes (157 words) - 14:24, 7 September 2017
- ==Event Handler configuration== ===Call Setup event===4 KB (635 words) - 01:59, 2 March 2023
- HTTP GET can be sent to third-party systems using EDO ports and Event Handler. ===Create Event===4 KB (557 words) - 00:56, 26 March 2024
- ...f these applications is the intercom (AMCd) application. Examples of other applications are [[SIP]], [[Syslog (AlphaCom)|Syslog]], [[AlphaWeb]] (web server) and [[ * Reboot the exchange. This will restart the Linux operative system and all applications. A reboot takes approx. xx seconds in a fully equipped E7, and xx seconds i2 KB (344 words) - 11:22, 8 September 2017
- ...nge, designed to provide critical communications and serve a wide range of applications. <br /> * [[Event Handler]]1 KB (155 words) - 13:31, 15 August 2017
- ==== Event Handler programming ==== The conference is started by dialing event trigger 9533 from the Bridge. UDD 500, which contains the current Active Us5 KB (837 words) - 14:35, 31 May 2022
- *Control room applications: No need for an additional intercom device at the desk. Use the computers a ...e to listen to any of these services, add the following event to the Event Handler:3 KB (378 words) - 08:19, 5 April 2024
- ...t box, and select the button '''Events'''. Press '''Insert''' to create an event with the following parameters (here RCO 1 is used as an example): [[File:Application_A3a.png|500px|left|thumb|Event for operating the RCO]]3 KB (428 words) - 11:01, 1 June 2022
- The '''Free Seating''' system runs on standard [[AMC]] SW using the [[Event Handler]] and the [[AlphaPro]] WACS module for swapping two users. The [[Event Handler]] is used to activate and send [[AlphaNet Data Protocol]] data messages to8 KB (1,173 words) - 11:31, 1 June 2022
- ==Creating Event for Door Opening == ...list to the left. Then select the button '''Events'''. '''Insert''' a new event with the following properties:7 KB (1,107 words) - 11:16, 24 October 2023
- * DAK1 = Leave blank in the DAK table (key press is triggering event 30) * DAK2 = Leave blank in the DAK table (key press is triggering event 30)9 KB (1,426 words) - 17:54, 2 February 2023
- The built-in [[Scheduler (Event Type)|Scheduler]] function in [[:category:ICX-AlphaCom Platform|ICX-AlphaCo Typical applications:5 KB (712 words) - 20:36, 22 July 2022
- * In order to make the [[Event Handler]] programming very general the [[AGA]] ports should be assigned directory n === Event Handler programming ===7 KB (1,079 words) - 11:13, 8 July 2022