Line 205: | Line 205: | ||
| align=center | %1.tag || align=center | %2.tag || align=center | || Mail tag. Unique mail identification. Available in mail related events only || AMC 06.00? | | align=center | %1.tag || align=center | %2.tag || align=center | || Mail tag. Unique mail identification. Available in mail related events only || AMC 06.00? | ||
|- | |- | ||
− | | align=center | % | + | | align=center | %3.chg || align=center | %3.chg || align=center | %chg || ON_txt when the event goes ON<br> |
+ | OFF_txt when the event goes OFF | ||
+ | Example: LOG “Door %1.dir is %chg(OPEN ,CLOSED)“ | ||
+ | Result, event ON: - “Door 123 is OPEN ” | ||
+ | Result, event OFF: - “Door 123 is CLOSED” | ||
+ | || AMC 06.00? | ||
|- | |- | ||
|} | |} |
Revision as of 15:19, 4 July 2007
The AlphaCom exchange is an intercom exchange of which the main task is to enable uni- and bi-directional speech. In order to be able to meet as many customer requirements as possible when it comes to special features an Event Handler has been implemented. The underlying idea is that by customer-programming this event handler functionality can be implemented which is not part of the standard feature list. The event handler is unique in the world of intercom. It is what gives the exchange its flexibility and makes it possible to meet most, if not all, customer requirements.
The Event Handler is based on the software concept that when the intercom functions run, they report 'events' to a part of the software called the Event Handler. The event can be described as a trigger that sets off an action in the system depending on the information entered in AlphaPro, the programming tool for the AlphaCom exchange. In this way, the Event Handler provides a powerful engineering tool for configuring system behaviour to meet requirements from customers.
Actions can be simple, just to operate a relay under certain circumstances. Actions can also be programmed using a scripting language and can include conditional statements. An action can itself trigger a new event, making it possible to start a chain of actions.
Contents
The principal
An event has an owner, the source which triggers the event. The following possible owners are defined:
- A single station
- A group of stations (UDP group) with common behaviour
- The scheduler, the internal AlphaCom clock which generates a ‘tick’ every minute
- EDI Text, a data port set up to receive ASCII text strings from external devices
In the case of the scheduler the event is the ‘minute tick’. Stations can trigger many different types of event.
Many events can trigger an action when the event is activated and when the event is de-activated, for instance event type 07: Conversation – Incoming. The On/Off action can be differentiated by the ‘When Change To’ flag.
Events can be, but don't have to be, related to a specific directory number or a group of stations, for instance:
- Owner: Station 1
- Event: Conversation - Outgoing
- Related to: Directory number 102
- When change to: ON
- Action: RCO 2 ON
In this case the relay connected to RCO 2 will only be activated if 'Station 1' is in conversation with a station with directory nr 102, AND if Station 1 was the station which made the call. If 'Related to' was not specified, that same relay would be activated on any call which Station 1 would make.
Events Types
The list shows the event types available, grouped by function.
Event Type | No. | When triggered |
---|---|---|
Single Station Events | ||
Audio | 01 | When audio is played in the speaker |
Door Open - Automatick Lock | 03 | When the Code Lock feature is dialed |
Station in Use | 04 | When a station becomes busy or free |
Microphone Open | 05 | When the microphone is alive |
Faulty Station Line | 13 | When a station is reported faulty or OK |
M-key | 31 | When the M-key is pressed or released |
Off-hook | 32 | When the handset is lifted or replaced |
Conversation Events | ||
Conversation Incoming | 07 | When a call is received |
Conversation Outgoing | 08 | When a call is made |
Private Ringing mode | 09 | During private ringing |
Door Opening - During Conv. | 02 | When door opening feature (digit 6) is activated during conversation |
Mail (Call Queue) Events | ||
Received Mail | 10 | When a mail or a call request is received |
Call Requester Mode | 13 | When a station sends a Call Request |
Priority Mail Present | 06 | When a mail with priority level 100 (programmable) is present in the mail queue |
Priority Mail in Idle | 12 | When a priority mail is present, and the station is not in conversation |
Mail Timeout | 20 | When a mail times out |
New Current Mail | 23 | When the current mail in the queue is changed |
New First Mail | 24 | When a new mail arrives first in the queue |
Conference Events | ||
Simplex Conference Audio | 16 | When listening to simplex conference, and the $VOX command is activated |
Simplex Conference Member | 17 | When a station joins a simplex conference |
Open Duplex Conf. Ringing | 18 | During ringing to an open duplex conference |
Open Duplex Conf. Connect | 19 | When a station connects to an open duplex conference |
Event Triggers | ||
Event Trigger | 15 | When dialing a directory number with feature number 52, 85, 95 or 105 |
Event Trigger with parameter | 25 | When dialing Event Trigger feature 95 or 105, preceeded by a directory number or digit |
Start: Event Trigger with param. | 26 | When dialing a directory number with feature number 95 |
Event Timeout | 21 | When a timer started by the $ST command expires |
Station DAK key as RCI | 30 | When a DAK key is pressed |
Scheduling | ||
Scheduler (Minute Tick) | 22 | When matching the specified date (or weekdays) and time |
EDI - External Data Input | ||
External Data Input | 28 | When receiving ASCII data on EDI port |
System Events | ||
System Status | 27 | When a device is reported up or down |
AlphaNet Link | 29 | When an AlphaNet link is reported up or down |
Action Commands
There are two types of Action Commands which can be used by the Event Handler, Built-In Action Commands and Data Protocol Commands.
Both type of commands can include parameters and macros (e.g. %1.dir and %clk(8))
Built-In Action Commands
Built-in Action Commands are three- or four-letter commands. The commands are case-insensitive as from AMC 08.20. Most of the Built-In commands also have a Data Protocol implementation.
Command | Description | From AMC ver. |
---|---|---|
PRS | Audio Program to Station | |
PRG | Audio Program to Group | |
CNG | Simplex Conference to Group | |
MST | Mail to Station | |
MGR | Mail to Group | |
MPP | Mail to Pocket Pager | |
AMS | Alarm Message to Station | |
AMG | Alarm Message to Group | |
RCO | Set Remote Control Output | |
EDO | Send text to serial port External Data Output EDO 1 - 4 | |
LOG | Send text to exchange’s log port (including date/time) | |
IND | Indicator control for CRMIV LEDs, buzzer etc. | |
OWN | Modify Event Owner (%1) and/or Related_To (%2) values | |
WUDD | Write a value to an User Defined Data UDD | |
TMP | Write a string to a temporary variable |
Data Protocol Commands
Data Protocol Commands are using ASCII commands in the Simple Link Layer format. The commands begin with $ or @. Data Protocol Commands became available for use in the Event Handler from software version AMC 08.00.
Parameters and macros
Action commands used in the Event Handler can contain parameters and macros. Parameters and macro operations in an action string are preceded by the '%'-sign. They both return a value.
Parameters are related to the actual event, and refer to the involved station(s) or functions.
- %1: the parameter is associated with the Owner field
- %2: the parameter is associated with the Related to field
- %3: the parameter is associated with the When change to field
A macro is unrelated to the event itself. It reads information from the memory (nvram) or performs a calculation. A macro always starts with the character "%".
Macros and parameters can be nested freely, and makes it possible to build complicated expressions.
List of parameters
Parameter assosiated with 'Owner' | Parameter assosiated with 'Related To' | Short name (owner) | Returned value | From version |
---|---|---|---|---|
%1.phy | %2.phy | %1p | The physical number | AMC 06.00? |
%1.dir | %2.dir | %1d | The directory number | AMC 06.00? |
%1.nam | %2.nam | %1n | The name (display text) | AMC 06.00? |
%1.exp | %2.exp | %1e | The External parameter field | AMC 06.00? |
%1.dak | %2.dak | %1hva | %1.dak(string,range) returns the number of the DAK key containing "string" | AMC 06.00? |
%1.nod | %2.nod | The node number | AMC 06.00? | |
%1.ref | %2.ref | The node and directory number %1.ref is equivalent to "L(%1.nod) %1.dir" |
AMC 06.00? | |
%1.mpri | %2.mpri | Priority of the mail. Available in mail related events only | AMC 06.00? | |
%1.mfre | %2.mfre | Free-text of station mail if available, else ”-”. Available in mail related events only | AMC 06.00? | |
%1.tag | %2.tag | Mail tag. Unique mail identification. Available in mail related events only | AMC 06.00? | |
%3.chg | %3.chg | %chg | ON_txt when the event goes ON OFF_txt when the event goes OFF Example: LOG “Door %1.dir is %chg(OPEN ,CLOSED)“ Result, event ON: - “Door 123 is OPEN ” Result, event OFF: - “Door 123 is CLOSED” |
AMC 06.00? |
- %n.dir(length,filler) :
- n can be 1 or 2
- empty () can be omitted; %n.dir is equivalent to %n.dir()
- shortform: %nd - %n.phy(length,filler)
- n can be 1 or 2
- empty () can be omitted; %n.phy is equivalent to %n.phy() - %n.nod()
- n can be 1 or 2 - %n.ref
- n can be 1 or 2 - %n.nam(length,filler) : returns the display text
- n can be 1 or 2
- shortform: %nn - %n.dak(DAK search string,D_10 range)
- n can be 1 or 2 - %n.exp : External Feature Parameter
- n can be 1 or 2 - %n.DEV : returns the device number (as from AMC 9.03).
- n can be 1 or 2
- if n equals 2, it will work only if the 'related to' parameter is a station in the same node - %n.BRD : returns the board number (as from AMC 9.03).
- n can be 1 or 2
- if n equals 2, it will work only if the 'related to' parameter is a station in the same node - %n.PORT : returns the port number (as from AMC 9.03).
- n can be 1 or 2
- if n equals 2, it will work only if the 'related to' parameter is a station in the same node - %3.chg(on_text,off_text)
- %3.chg(,) can be shorted to %chg(,) - %3.RFT(normal_text,refresh_text) : Action command parameter which substitutes the parameter with a text describing the on/off transition of the event. Some events can be reported many times (e.g. line errors), and it's possible to have different actions depending on if this is the first time, or a ReFresh.
- can be shorted to %3r(on_text,off_text) - %1.mpri : returns the priority of the mail
- %1.mfre : returns the free text of a station mail if it is available, otherwise '-'
- %1.tag : returns the mail tag
- %sng(station, group) : (Station Next Group). Returns the next group after group of which station is a member. Returns '0' if station is not a member of any (more) groups. %sng(station, 0) returns the first group of which station is a member.
- group is 1 – 100, station is physical number 0 – 552. - %gns(group, station) : (Group Next Station). Returns the next station after station which is a member of group. Returns ‘0’ if no more members in group. %gns(group, 0) returns the first station in group.
- group is 1 – 100
- station is physical number 0 – 552. - %sgm(station,group) (Station Group Membership). Returns '1' if station is a member of the group.
- group is 1 – 100
- station is physical number 0 – 552. - %UDD(index) : Command string macro to get the User Defined Data out of the location 'index'.
- %SEV : Returns the sub-event number (in decimal format) of the event being processed. If the sub-type of en event is defined as 255, the main event will be triggered independent on the reported sub-type. If this is used with feature 105, 'Event trigger on dialling digits', %SEV will return the dialled digit. (introduced in AMC software 9.03)
- %OP( , , ) : macro for numeric calculations. The general format is %OP(integer1,operator,integer2), no space is allowed between ',' and the operator. The operator can be:
- + add
- - subtract
- * multiply
- / divide
- < less
- <= less or equal
- > greater
- >= greater or equal
- = equal
- == equal
- != not equal
- << bit shift left / up
- >> bit shift right / down
- && logical and
- || logical or
- & bitwise and
- | bitwise or
- ! logical not of second operand
- ^ bitwise xor - %clk
- returns current date/time 2000-11-10 12:59:35 - %clkyear
- returns current year: 2000 - %clkmon
- returns current month: 11 - %clkday
- returns current day: 10 - %clkhour
- returns current hour: 12 - %clkmin
- returns current minute: 59 - %clksec
- returns current second: 35 - %clkwday
- returns current day of week: 5 (1 = monday, 7 = sunday) - %1.clk, %1.clkmin %1.clkhour etc. will return the scheduling tick time, not the real time if used within a Scheduling action.
- %GNV() : returns the value of the NVRAM-parameter, of which the address is specified in between () (as from AMC 9.05).
- %GNV(1,3,54) returns the value of 'ex_profile.timeouts.th_conn_length' in AMC 9.05. Note that the address can be different in different AMC software versions.
Statements
PAUSE pauses the event handler command interpreter for 100ms
IF/ENDIF Conditional statement. If the text/expression after the keyword IF evaluates to ‘0’, all following commands/statements are skipped until the keyword ENDIF is encountered; IF/ENDIF statements can be nested
STOP The statement STOP stops the execution of the action string. Is only useful in front of the keyword ENDIF